Sales : Support :
Registered in England and Wales company # 03449181.
This website does not use cookies.
© Copyright: Conwy Valley Systems Limited 2000 - 2025
Conwy Valley Systems Limited,
West Acre, Llys Helyg, Deganwy
CONWY LL31 9BN, United Kingdom.
VAT# GB 741 5190 48
A Geoscience Wales founding member.
PETROG includes patent protected technology.
Release date : 2025-05-22
PETROG
New features
Support for multiple lighting conditions when working with whole slide images, and related enhancements to the import options for whole slide images, facilitating a workflow for importing multiple channels from Zeiss CZI slide scans and being able to manage the displayed lighting conditions and additional "magic mouse" viewing tool options whilst working with these images.
New workflow for logging grain coat data for Touchstone - following a standard first pass to collect compositional data, there is now a new "Revisit Logged Points" option for textural data collection which facilitates revisiting of specific points e.g. just Detrital Quartz grains, for collection of outline data and grain coat data, including specific options for Touchstone.
Related improvements to grain outline logging generally
For Touchstone, any nodes not tagged are counted as unavailable (so coated + uncoated + unavailable = 100);
now applies defaults from Data Collection Options for node size, tagging mode and display of calculated major/minor axes; other fixes.
There is now 'edit' functionality when collecting outline data, so that nodes can be deleted or re-positioned easily, without the need to delete the polygon and start again.
Improvements to reporting of outline logging data for Touchstone.
Enhancements
Saving images: It is now possible to modify the folder location where images are stored for a particular project, and at the same time choose whether to make this a new site default to be applied for future projects. This is useful for either archiving images for older projects to free up space, or for changing the path for saving images for all future projects (for instance to save them on an external disk or SD card).
Hardware combination
Improvements to microscope and camera configuration windows, making it easier to change the name of a camera or microscope, change the defined objectives for a microscope, etc.
Under Hardware Combination selection, it is now possible to archive a selected hardware combination, in order that it remains in the database (so it is still present if reviewing data from older projects that was collected with this hardware combination) but is now no longer considered as "active", so that when setting up new projects and samples, the software is better able to select the correct hardware combination to apply - generally there will just be one active "physical" (i.e a physical microscope and camera, as opposed to working with virtual or imported images) hardware combination to default to, as archived hardware combinations are no longer considered.
PETROG Exchange
Fixed some issues with exporting/importing projects with textural data;
Extended the format to support comments logged during data collection, and also to now work when working with samples across multiple wells.
Cameras
General - fixed a bug related to setting of frame rate value for certain cameras; fixed a bug relating to updating of Red, Green and Blue slider controls when processing changes to colours;
GTVision - certain GTVision USB cameras are now supported in a new version;
Jenoptik - changes relating to white balance - now calls a subroutine that continues to attempt to get a new frame until success or a specified maximum number of attempts is reached; also modified the message displayed if this is not successful (it is nothing to do with the frame being too dark, it is that there is no frame)
NnCam (Toupcam) - upgraded to work with an updated version of the nncamsdk (20241103);
Olympus SIS / Evident - upgraded to latest SDK, in order to add support for LC35 camera;
addition of gray/luminance parameter, and hooking up load/save from/to registry;
Hardware ROI - now works without errors, but is not giving better performance than software ROI.
Zeiss - application of sensible defaults when loading from registry if no information found.
Improvements
More diagnostic messaging to reduce possibility of error messages being obscured by image window;
'Apply To' (applying properties to other samples) - changes with regards to 'Area of Interest', to provide a warning if this is selected as one of the properties, so that the user must confirm their intention before potentially overwriting the existing AoI for multiple samples;
When working with virtual images, the setting of motion blur (on/off) is now available in all camera versions and persistent via registry;
Improvements to image window position/size management, specifically to prevent the case where a window can be stuck in a minimised state under Windows 10.
Bug fixes
Fixed a problem when logging trace items during concurrent logging; other related changes whilst testing with concurrent, on skips / back button etc.;
fixes when checking lengths of logged strings when over-writing compositional data after a Back command;
Arc of ellipse for AoI half-moon was drawing incorrectly because y semi-axis was calculated incorrectly;
Fixed errors if 'Virtual' is selected as image source but there are no virtual images available for the current sample;
Disable parts of the window when collecting images for stitching, so that settings cannot be changed mid-way through collection;
Fixed a bug in standalone textural data collection (auto move mode, major lengths only).
PetrogLite v5.7.0
Preventing a 'division by zero' when switching to oversize (Y) AoI when no AoI is defined; and some textLogger messages when calculating AoI/stepping pattern are now "don't show" (otherwise end up repeating them repeatedly in the case that the AoI has not yet been properly defined);
Fixes in the Set AoI window, so that the buttons are always correctly displayed, positioned and captioned when switching from any AoI shape to another;
Fix in for error in displayed "change" percentages during logging;
Fixes relating to checking of logging files that include skips, as these were reporting errors due to sum mis-matches between the lg1 and lg2 file.
Academic and Research |
Oil & Gas |
Coal |
Concrete |
Ceramics in Archaeology |
Cement Clinker |
Scanned Images, Archive & AI |
Asbestos |
Scanned Images |
Archives and Legacy Data |
AI & Machine Learning |
PETROG |
PetrogLite |
SteppingStage |
PETROG Virtual Keyboard |
Cameras |
Additional Services |
Features |
Who Uses Petrog ? |
Demonstrations |
FAQ (PETROG) |
Upgrade from PetrogLite |
Enquiries |
Custom Work Flow and Protocols |
Data Structures |
Data Capture & Analysis |
Sample Scanning |
Reporting |
Data : Storage & Exchange |
Area of Interest |
Set Area of Interest |
Compositional Analysis Methodology |
Compositional Data |
Textural Data |
Qualifiers and Relationships |
Microporosity |
Microporosity and XRD |
Dictionaried Lists |
Point counting Application |
Compositional Data Entry Image |
Quantitative Composition Summary |
Photo stitching |
Report Document |
Triangular Diagram |
Compositional Plot |
Rose Diagram |
Kite Diagram |
Concentric Pie Chart |
Grain Size Analysis |
Data Storage |
Data Exchange |
Touchstone |
Where is Petrog ? |
Testimonials |
Replacing a point counter |
Point Counting |
System Requirements |
Software |
Gallery |
Enquiries |
10 years of the SteppingStage |
Espanol |
PVK with PetrogLite |
Cameras and PETROG |
Supported Cameras |
HDMI Cameras |
Discontinued Cameras |
Training |
Downloads |
Change log |
FAQ (Support) |
Known issues |
Future |
PETROG 5 |
PetrogLite 5 |
PETROG Virtual Keyboard |
Tutorials |
YouTube |
Older versions |
PETROG 5 Upgrade |
PETROG 5 Installation |
Documentation |
PetrogLite 5 Upgrade |
PetrogLite 5 Installation |
Documentation |
PETROG 4 |
PetrogLite 4 |
PETROG 3 |
PetrogLite 3 |
PETROG 4 Upgrade |
PETROG 4 Installation |
Documentation |
PetrogLite 4 Upgrade |
PetrogLite 4 Installation |
Documentation |
PETROG 3 Upgrade |
PETROG 3 Installation |
Documentation |
PetrogLite 3 Upgrade |
PetrogLite 3 Installation |
Documentation |
5.7.0 |
5.6.0 |
5.5.4 |
5.4.0 |
Version 5 (earlier) |
Version 4 |
Version 3 |
Version 2 |
5.3.6 |
5.3.1 |
5.3.0 |
5.2.0 |
5.1.2.0 |
5.1.1.0 |
4.8.0.0 |
4.7.1.0 |
4.6.1.0 |
4.5.8 |
4.5.6 |
4.5.5 |
4.5.0 |
4.4.2 |
4.2.2.0 |
4.2 |
4.1.0.1 |
4.0.2.1 |
4.0.0.0 |
3.7.1.0 |
3.6.1.0 |
3.6.0.1 |
3.5.3.0 |
3.5.1.0 |
3.5.0.1 |
3.4.0 |
3.3.0 |
3.2.2.0 |
3.2.1.0 |
3.1.9.9 |
3.1.9.4 |
3.1.9.1 |
3.1.9.0 |
3.1.8.0 |
3.1.6.0 |
3.10 |
3.05 |
3.02 |
3.01 |
2.68 |
2.67 |
2.66 |
2.65 |
2.64 |
2.45-2.63 |
Windows 7 Installation |
PETROG 64-bit |
"Out of Resources" (2020) |
Control Box Chip Upgrade (2009) |
USB - Serial connection |
News 2023-24 |
News 2022 |
News 2021 |
News 2020 |
News 2019 |
News 2018 |
News 2017 |
News 2016 |
News 2015 |
News 2014 |
News 2013 |
News 2012 |
News 2011 |
News 2010 |
Nikon Small World 2013 |
Regional Support |
Newsletter |
Newsletter Archive |